Eagle-tree eLogger V4 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Audio-Zubehör Eagle-tree eLogger V4 herunter. Eagle Tree eLogger V4 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 17
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Copyright © 2003-2010 Eagle Tree Systems, LLC
Instruction Manual for the eLogger V4
Document Version 1.7,
Model # MPRV4-CONN-100,
MPRV4-LEADS-100, and
MPRV4-LEADS-150
Thank you for your purchase! This instruction
manual will guide you through the installation and
operation of your eLogger.
Please read the entire manual carefully before
proceeding. If, after you read the manual
(including the Troubleshooting sections!) you have
further questions or problems, please visit our web
support page for additional support options, at
http://www.eagletreesystems.com/Support/support.ht
ml. Note that the latest version of this manual is
available in PDF form from the Support page of our
website.
Please also fill out the registration form at the end of
this manual if you did not purchase your eLogger
directly from Eagle Tree Systems, so we can send
you important update information.
Intended Uses
The eLogger V4 is intended to be used exclusively
for recreational purposes in model planes, boats and
cars. Using the eLogger for other purposes is not
supported. Further, using the eLogger in situations
where its use or failure could result in loss of life,
bodily injury or property damage is expressly
prohibited. Eagle Tree Systems, LLC, is not
responsible for your use of this product, or for
any damages or injuries you may cause or sustain
as a result of its usage.
Key Features
Here are a few of the features of the eLogger:
Logs pack current to +/- 100 amps peak (150 amps peak with MPRV4-LEADS-150) and voltage from about 5
volts to 80 volts
Current is measured with a Hall Effects Sensor
Adjustable logging rate (from 50 samples per second to one sample every 5 minutes)
16 times the logging space of the standard eLogger V3, and lossless data compression. Typically logs all
available sensors for about four hours, at 10Hz.
All data are logged to permanent memory, which retains the data even when the power is removed
Fully compatible with our OSD Pro expander
Includes Y cable for throttle position logging
Seitenansicht 0
1 2 3 4 5 6 ... 16 17

Inhaltsverzeichnis

Seite 1 - Intended Uses

Copyright © 2003-2010 Eagle Tree Systems, LLC Instruction Manual for the eLogger V4 Document Version

Seite 2 - Installation of the eLogger

Copyright © 2003-2013 Eagle Tree Systems, LLC Page 10 Note: Select the “Metric” checkbox on this dialog if you want values displayed in metric

Seite 3

Copyright © 2003-2013 Eagle Tree Systems, LLC Page 11 function test your model once the eLogger is installed to ensure that there is no impact on

Seite 4

Copyright © 2003-2013 Eagle Tree Systems, LLC Page 12 • Graphical and/or Numeric Temperatures – The software can display up to three Temperature

Seite 5

Copyright © 2003-2013 Eagle Tree Systems, LLC Page 13 The eLogger’s Data File is compatible with Excel ™ spreadsheet software, and other spreads

Seite 6

Copyright © 2003-2013 Eagle Tree Systems, LLC Page 14 There are many advanced features included with our software, available via the “Advanced” ta

Seite 7

Copyright © 2003-2013 Eagle Tree Systems, LLC Page 15 • Connect the eLogger to the computer and launch the Windows Software. Then, click the “L

Seite 8

Copyright © 2003-2013 Eagle Tree Systems, LLC Page 16 eLogger Specifications Voltage Measurement: approx 5V to 80V Voltage Resolution: approx 0.

Seite 9

Copyright © 2003-2013 Eagle Tree Systems, LLC Page 17 Eagle Tree Systems Warranty Product Registration: Name:____________________________________

Seite 10 - Using the eLogger

Copyright © 2003-2013 Eagle Tree Systems, LLC Page 2 • Great for bench monitoring of battery charging also! • Supports the PowerPanel LCD Displ

Seite 11 - After Your Recording Session

Copyright © 2003-2013 Eagle Tree Systems, LLC Page 3 IMPORTANT: Do not leave your model’s power system connected to the eLogger when the unit is

Seite 12

Copyright © 2003-2013 Eagle Tree Systems, LLC Page 4 To install our magnets, first find a suitable location on your motor or drive train to attach

Seite 13 - Advanced Software Features

Copyright © 2003-2013 Eagle Tree Systems, LLC Page 5 Several of our customers have been able to use existing RPM sensors, such as governors or tu

Seite 14 - Troubleshooting

Copyright © 2003-2013 Eagle Tree Systems, LLC Page 6 Installing and Using the Windows™ Software The eLogger V4 is configured, and data is downlo

Seite 15

Copyright © 2003-2013 Eagle Tree Systems, LLC Page 7 Setting up the eLogger with the Windows Software Once the software is installed, run the sof

Seite 16 - Limited Warranty

Copyright © 2003-2013 Eagle Tree Systems, LLC Page 8 The more items you log, the less record time will be available. A description of the

Seite 17 - Page 17

Copyright © 2003-2013 Eagle Tree Systems, LLC Page 9 In our experience, if all sensors are connected and logged, and the capture rate is set to

Kommentare zu diesen Handbüchern

Keine Kommentare